MAINTENANCE
GRASS KING 03/09 Maintenance Section 5-3
© 2009 Alamo Group Inc.
MAINTENANCE
HYDRAULIC OIL, FILTERS, & COMPONENTS
Filters and Oil - Change the return filter in the tank after the first 200 hours of operation. Change the filters
again at 800 hours; then, change the oil and filters at 1600 hours. After that, continue to change the filter every
800 hours and the oil every 1600 hours. Hydraulic oil to be Chevron 1000 THF or equivalent. Use SAE 90 wt.
in Speed Increaser. Use the above procedures as part of a good filter maintenance program.
Note: Your ambient temperature and operating conditions may require a different viscosity oil. Please consult
the oil manufacturer for proper specifications.
RESERVOIR
The reservoir stores hydraulic system oil. The breather cap which is mounted on top of the reservoir prevents
an extreme pressure buildup or vacuum from occurring in the tank as oil level changes. There is also an oil
filler cap which is used to fill the reservoir with oil. To help prevent dirt from entering the tank, clean the top of
the reservoir before removing the cap. THE BREATHER CAP HOLDS APPROX 11 PSI PRESSURE IN TANK.
REMOVE FILLER CAP SLOWLY
The oil level sight glass is located on the back of the reservoir. The oil level should be even with the sight glass
and checked with the cutter unit in the transport position. The oil temperature should not exceed 180 degree F.
The oil return hoses are connected to the hydraulic filter on top of the reservoir. Oil is returned from cutter unit
cooling tubes and filtered before entering the hydraulic reservoir. Oil returning from the control circuit also
enters the reservoir through the filter.
PROPER OIL LEVEL
Maintain the oil level within the sight gauge located on the side of the reservoir. Never fill the tank above the
sight gauge level. A space is maintained above the sight gauge to allow for the expansion of the oil. The tank
maintains pressure after the mower has been run. Stand off to one side when removing the breather cap
element to prevent possible injury. To relieve pressure, remove the breather cap element and depress the
spring loaded pressure valve to release any excess air. Fill with Universal Tractor Hydraulic Oil.